The warranty does not apply to any product where the serial number has been removed or obliterated. The warranty also does not apply to any product sold by a reseller to an end user outside of the country where the reseller is located unless (i) Christie has an office in the country where the end user is located or (ii) the required international warranty fee has been paid.
Safety precautions Learn about the safety precautions related to the Christie CP2208-LP projector. Product labels Learn about the labels that may be used on the product. Labels on your product may be yellow or black and white. General hazards General hazard.
SHOCK HAZARD! The AC power cord must be inserted into an outlet with grounding. • SHOCK HAZARD! A dedicated, protected earth wire must be installed on the product by Christie qualified technicians or electricians before it can be connected to power.
SHOCK HAZARD! Power supply uses double pole/neutral fusing. Disconnect all power sources before opening the product. • Only Christie qualified technicians are permitted to open product enclosures. Light intensity hazard distance This projector has been classified as Risk Group 3 as per the IEC62471-5 standard due to possible hazardous optical and thermal radiation being emitted.
Introduction This manual is intended for operators of Christie CP2208-LP projection systems. Projector components (front) Learn about the components on the front of the projector. Touch panel controller (TPC) A touch-sensitive screen used to control the projector. Communications panel External devices are connected here.
A green LED indicates the item is functioning correctly. A yellow LED is a warning that a projector item requires attention. A red LED indicates a projector item requires immediate attention. If the Interlocks status LED is yellow or red, contact Christie technical support. 1. On the touch panel controller (TPC), tap Menu > Status.
Running the projector interrogator The interrogator captures diagnostic information that you can use to assist Christie service technicians diagnose and correct projector issues. Image disruption can occur if you run the interrogator during a show. When you run the interrogator, you cannot modify projector settings.
The baud rate of the serial port. The default is 115200. Enable SNMP Enables SNMP. SNMP V2 / SNMP V3 The SNMP protocol type. Contact Christie for the SNMP V3 user ID and password. Management IP The IP address where SNMP information and notifications are sent.
Accessing a network device Learn how to interact with network devices. 1. On the touch panel controller (TPC), tap Menu > Network Devices > Christie ACT. 2. To interact with the device tap in the top-right corner of the window.
Troubleshooting The following topics cover common projector issues and their solutions. If an issue cannot be resolved, contact a Christie qualified technician. Projector functionality The following topics cover common projector issues and their solutions. Projector does not turn on When I attempt to power on the projector, it does not turn on.
Increase the power. • A fold mirror, light module, or integrator rod misalignment could exist. Contact your Christie qualified service technician to resolve the issue. Blank screen with no display of cinema image When the projector is turned on, nothing is displayed.