10. Loosen the cathode clamp with the 5 mm hex key attached to the lamp door.
11. For CDXL-14 or CDXL-16 lamps:
Caution! Failure to comply with the following could result in minor or moderate injury.
Handle the lamp by the cathode/anode end shafts only, never the glass. DO NOT over-
tighten. DO NOT stress the glass in any way. Check leads. Ensure the anode (+) lead
between the lamp and igniter is well away from any projector metal, such as the reflector or
fire wall.
a. Install the lamp extension nut on the cathode clamp. To provide access to the locking
screw on the extension nut, rotate the extension nut until the locking screw faces upward
toward the projector lid.
b. Tighten the cathode screw (D) with a hex key.
c. Thread on and hand-tighten the cathode nut. Ensure the smooth portion of the nut is
against the cathode clamp.
CP2208 User Manual
020-101916-02 Rev. 1 (08-2015)
Anode Terminal
A
Anode Wire
B
Reflector
C
Cathode Screw
D
Cathode Nut
E
Cathode Clamp
F
Installing and Setting Up