Adjustments and Calibrations
Scanner Calibration
6-8
This process enables manual calibration of the registration adjustment value
or correction value. Use this procedure to enter the correction value when
replacing the scanner.
Note
Note the ADF Scanner correction values under the ADF Scanner
Assembly prior to installing the ADF Scanner Assembly to the printer.
Index(Hex) Value(Hex)
Note
The information in the table below is for reference only. Each scanner has
its own calibration information.
FB - GS6JW0000501, ADF - GD6JW0000501
0x04 : 52
0x08 : 46
0x05 : 2B
0x09 : 21
0x06 : 1E
0x0A : 1E
0x07 : 26
1.
Turn the printer power Off.
2.
Access the Service Diagnostics menu by pressing and holding the Up
and Down Arrow buttons simultaneously and turn the printer power On.
3.
The
Service Mode
is displayed. Select Fax/Scanner Diag and press the
OK button.
4.
Press the Up Arrow or Down Arrow button to find
Maintenance. Press the OK button.
5.
Press the Up Arrow or Down Arrow button to find Parameter. Press the
OK button.
>PET<
0x0F : 56
0x13 : 5D
0x10 : 5D
0x14 : 64
0x11 : 5D
0x15 : 66
0x12 : 59
0x16 : 62
s6180mfp-395