Phaser 6180MFP Multifunction Printer Service Manual
Drum Erase Lamp Y/M/C
Caution
When performing this procedure, remove and cover the Print Cartridges
to avoid exposure to light if the Front Door will be opened for prolonged
periods.
1.
Enter the Service Diagnostic menu (page 4-5).
2.
Open the Front Cover.
3.
Remove the Print Cartridges (page 8-11).
4.
Use a paper clip to secure the Interlock Switch.
5.
Perform the Drum Erase Lamp YMC test:
Motor Test
6.
Verify that the Lamps are operating.
7.
Press the Stop button to stop the Drum Erase Lamp YMC test.
8.
Remove the paper clip from the Interlock Switch.
>
Drum Erase Lamp
Cyan Erase Lamp
General Troubleshooting
Printer Diag
>
Engine Diag
YMC.
Magenta Erase Lamp
Yellow Erase Lamp
>
s6180mfp-194
4-75