Xerox Phaser 6180MFP Service Manual page 447

Multifunction printer
Hide thumbs Also See for Phaser 6180MFP:
Table of Contents

Advertisement

Phaser 6180MFP Multifunction Printer Service Manual
Fax/Scanner Diag
Test
Control Panel Display
FPGA Test
1st FPGA I/F
1st FPGA I/F Test
Test
Ready
Now Checking
Check OK/Check NG
2nd FPGA I/F
2nd FPGA I/F Test
Test
Ready
Now Checking
Check OK/Check NG
Video Memory
Video Memory Test
Test
Ready
Now Checking
Check OK/Check NG
Relay/Signal
Test
Relay Test
Relay Test
<Press the Left or Right
button to move the
cursor>
<Press the Up or Down
button to change the
value at the cursor>
<Press the OK button to
save the value in Engine
NVM>
<Press the Exit button to
move one level up the
menu>
Relay Toggle
Relay Toggle Test
Test
Time [10ms]:0000
Now Switching
Relay Set Test
Relay Set Test
Set ON [OPEN]
Set OFF [CLOSE]
Complete
<Press the Up or Down
button to change the
value at the cursor>
Hook Test
Hook Test
General Troubleshooting
Test Description
Tests the register area of FPGA from
2nd.Fire Chip. This test generates
accesses from 1st Fire to the register
space of FPGA. Run this test when
communication errors occur between
Fax and Scanner occur.
Tests the register area of FPGA from
1st.Fire Chip. This test generates
accesses from 2nd Fire to the register
space of FPGA. Run this test when
communication errors occur between
Fax and Scanner occur.
Performs read/write/verification on the
Video Memory. Run this test when
error occurs: 017-970, 033-503, 062-
324, or 133-254.
Switches the relay circuit between the
Fax and telephone.
This test switches the relay circuit ON/
OFF between the Fax and telephone line
at a predetermined cycle.
Toggle test value can be set in the
range of 50 to 9999, and the toggle
interval is 10ms.
Data 1: Default is 2 seconds.
This test connects the relay circuit
selectively to the Fax or telephone line.
Set ON (open): Connected selectively
to the Fax line.
Set OFF (closed): Connected
selectively to the telephone line.
Switches the telephone line between
the on-hook and off-hook states.
4-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phaser 6180mfp/nPhaser 6180mfp/d

Table of Contents