Event code: 512
Message:
Optical transceiver nonfatal error.
Severity:
Minor.
Explanation:
Switch firmware detected an optical transceiver non-fatal error.
Action:
Replace the failed transceiver with a functional transceiver of the same type.
Event data:
Byte 0 = port number.
Byte 1 = engineering reason code.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = optic serial number.
Distribution:
Product
EFCM Basic
Event Log
Event code: 513
Message:
Optical transceiver hot-removal completed.
Severity:
Informational.
Explanation:
An optical transceiver was removed while the switch was powered on and operational.
Action:
No action required.
Event data:
Byte 0 = port number.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = optic serial number.