c. Select (click) the Speed field and configure the port.
d. Click OK or Activate.
Was the maintenance action successful?
NO
YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
16
A port is inactive because the port swap configuration is invalid.
Perform a port swap procedure (Element Manager only), ensure the
configuration is valid, and ensure the port address matches the
hardware configuration definition (HCD) of the attached host. Refer to
Swap
ports. Exit MAP.
17
As indicated by event codes 506, 512, 514, 515, or 516, a port failed
and the optical transceiver must be removed and replaced. Refer to
Customer-replaceable unit: SFP optical
The procedure is concurrent and performed while the product is
operational.
Replace the transceiver with a transceiver of the same type
(shortwave or longwave) and speed.
Perform an external loopback test. Refer to
test
(EFCM Basic Edition) or
Manager).
NOTE: Event code 514 may generate a call-home event that incorrectly
indicates a CTP card failure. Although the optical socket on the CTP card
may have failed, replace the transceiver and verify operation. If a failure is still
indicated, replace the switch. When event code 514 is indicated, ensure a
replacement transceiver and switch are available.
Was the maintenance action successful?
NO
YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
transceiver.
External loopback test
Chapter 3: Maintenance analysis procedures
External loopback
(Element
131