IBM TotalStorage SAN32M-2 Installation And Service Manual page 162

Hide thumbs Also See for TotalStorage SAN32M-2:
Table of Contents

Advertisement

136
SAN32M-2 Installation and Service Manual
3
As indicated by event code 051, a minor error occurred that caused
the Management Server database to be re-initialized to an empty
state and fail CRC validation. A disruptive server logout and login
occurred for all attached devices.
Devices resume operation after Management Server login. Perform a
data collection and contact the next level of support. Refer to
maintenance data
(EFCM Basic Edition) or
(Element Manager). Exit MAP.
4
As indicated by event code 061, a minor error occurred that caused
the Fabric Controller database to be re-initialized to an empty state
and fail CRC validation. The product briefly lost interswitch link
capability.
Interswitch links resume operation after CTP reset. Perform a data
collection and contact the next level of support. Refer to
maintenance data
(EFCM Basic Edition) or
(Element Manager). Exit MAP.
5
As indicated by event code 062, Fabric Controller software detected a
path to another fabric element (director or switch) that traverses more
than three interswitch links (hops). Fibre Channel frames may persist
in the fabric longer than timeout values allow.
Advise the customer of the problem and reconfigure the fabric so the
path between any two fabric elements does not traverse more than
three hops.
Was the maintenance action successful?
NO
YES
The fabric, ISL, and product are operational. Exit MAP.
Contact the next level of support. Exit MAP.
6
As indicated by event code 063, Fabric Controller software detected:
A fabric element with more than 32 ISLs (SAN management
application Version 3.2 or earlier).
A fabric element with more than 128 ISLs (SAN management
application Version 3.3 or later).
Collect
Collect maintenance data
Collect
Collect maintenance data