Chapter 5: Removal and replacement procedures

Procedural notes

ESD procedures

© Copyright IBM Corp. 2006
This chapter describes part removal and replacement procedures
(RRPs) for the SAN32M-2 switch. The chapter also provides
procedural notes, electrostatic discharge (ESD) precautions, and list
of the parts.
NOTE: This section covers both CRUs, customer-replaceable units that are
SFPs only, and FRUs (the power supply), field-replaceable units to be
replaced only by service personnel.
Observe the following procedural notes:
1. Follow all ESD precautions and DANGER, CAUTION, and
ATTENTION statements.
2. Do not perform an RRP unless a failure is isolated to a part. If
fault isolation was not performed, refer to
3. Before removing a part, read the associated RRP to familiarize
yourself with the procedure.
4. After completing an RRP:
— Clear the event codes reporting the failure and recovery from
the product Event Log.
— Extinguish the amber system error light-emitting diode (LED)
at the product front panel.
Follow these ESD procedures:
If the product is connected to facility power (grounded), wear an
ESD wrist strap and grounding cable connected to the product
chassis.
If the product is not connected to facility power (not grounded),
wear an ESD wrist strap and grounding cable connected to an
approved bench grounding point.
MAP 0000: Start
MAP.
201