IBM TotalStorage SAN32M-2 Installation And Service Manual page 151

Hide thumbs Also See for TotalStorage SAN32M-2:
Table of Contents

Advertisement

Invalid attachment reasons and actions (Continued)
Table 15
Byte 4
Invalid attachment reason
08
E_Port capability disabled.
0A
Unauthorized port binding WWN.
0B
Unresponsive node.
0C
ESA security mismatch.
0D
Fabric binding mismatch.
0E
Authorization failure reject.
0F
Unauthorized switch binding WWN.
10
Authentication failure
11
Fabric mode mismatch.
4
A connection is not allowed because of a conflict with the configured
port type. An expansion port (E_Port) is cabled to a Fibre Channel
device or a fabric port (F_Port) is cabled to a director or switch.
a. For the product reporting the problem:
— EFCM Basic Edition - Select Ports and Basic Info from the
Configure menu at any view. The Basic Information View
displays.
— Element Manager - Select Ports from the Configure menu
at any view. The Configure Ports dialog box displays.
b. If necessary, use the vertical scroll bar to display the information
row for the port indicating an invalid attachment.
c. Select (click) the Type field and configure the port as follows:
Select fabric port (F_Port) if the port is cabled to a device.
Select expansion port (E_Port) if the port is cabled to a
director or switch (ISL).
d. Click OK or Activate.
Chapter 3: Maintenance analysis procedures
Action
Go to
step
7.
Go to
step
2.
Go to
step
8.
Go to
step
10.
Go to
step
11.
Go to
step
8.
Go to
step
10.
Go to
step
12.
Go to
step
5.
125

Advertisement

Table of Contents
loading