Configure and enable Ethernet events

84
SAN32M-2 Installation and Service Manual
4. Type the IP address or DNS host name of the SMTP server in the
E-mail Server field.
5. Type the e-mail address to which replies should be sent in the
Reply Address field.
6. At the Summary Interval field, type the length of time the
application should wait between notifications. Choose seconds,
minutes, or hours from the associated drop-down list.
7. To specify users for notification, click User List. The SANavigator
Server Users or EFCM Server Users dialog box displays.
8. To enable notification for a user, select (click) the check box in the
Email column. An unchecked box indicates e-mail notification is
not enabled.
9. Click OK to close the SANavigator Server Users or EFCM Server
Users dialog box.
10. At the E-mail Test Options field, select the Send to radio button
(and type recipient IP addresses in the adjacent field), or select the
Send to all users enabled for notification radio button.
11. Click Send Test Email. A test message is sent to configured
recipients.
12. Click OK to save the information and close the dialog box.
13. Maximize the Element Manager application.
14. Select Enable E-Mail Notification from the Maintenance menu at any
view. A check mark appears to indicate e-mail notification for the
product is enabled.
NOTE: The enable function must be activated for each product through
the Element Manager application.
Perform this procedure to configure and enable Ethernet events. An
Ethernet event is recorded (after a user-specified time interval) when
the switch-to-management server communication link drops. To
configure and enable Ethernet events: