Field-replaceable unit: Redundant power supply

Removal
206
SAN32M-2 Installation and Service Manual
a. Ensure alert symbols do not appear (yellow triangle or red
diamond).
b. Double-click the port graphic to open the Port Properties
dialog box. Verify port information is correct.
c. Right-click the port graphic and select Port Technology from
the menu. The Port Technology dialog box displays. Verify
the port technology is correct.
If a problem is indicated, go to
problem.
9. Restore communication to the port as directed by the customer.
Refer to
Block or unblock a port
unblock a port
(SAN management application) for instructions.
Inform the customer the port is available.
10. Clear the system error LED on the product front bezel:
— At a web browser communicating with the EFCM Basic
Edition interface, select Clear System Error Light from the
Maintenance menu.
— At the management server (Element Manager application),
open the Hardware View. Right-click the front panel bezel
graphic (away from a FRU/CRU), then click the Clear System
Error Light menu selection.
11. If necessary, close and lock the equipment cabinet door.
NOTE: These instructions are for service personnel only.
The redundant power supply should be replaced by service
personnel only.
Refer to
Chapter 6, Illustrated parts breakdown
part numbers.
To remove a redundant external power supply:
1. If the product is not rack-mounted, go to
rack-mounted, unlock and open the cabinet door (front or rear) as
directed by the customer representative.
MAP 0000: Start MAP
to isolate the
(EFCM Basic Edition) or
for part locations and
step
2. If the product is
Block or