System Events (000 Through 199) - IBM TotalStorage SAN32M-2 Installation And Service Manual

Hide thumbs Also See for TotalStorage SAN32M-2:
Table of Contents

Advertisement

System events (000 through 199)

Event code: 011
Message:
Login Server database invalid.
Severity:
Minor.
Explanation:
Following an initial machine load (IML) or firmware download, the Login Server database failed cyclic redundancy
check (CRC) validation. All fabric service databases initialize to an empty state, resulting in implicit fabric logout
of all attached devices.
Action:
Perform a data collection and return the CD to support personnel.
Event data:
No supplementary data included.
Distribution:
Product
EFCM Basic
Event Log
Event code: 021
Message:
Name Server database invalid.
Severity:
Minor.
Explanation:
Following an IML or firmware download, the Name Server database failed CRC validation. All fabric service
databases initialize to an empty state, resulting in implicit fabric logout of all attached devices.
Action:
Perform a data collection and return the CD to support personnel.
Event data:
No supplementary data included.
Distribution:
Product
EFCM Basic
Event Log
220
SAN32M-2 Installation and Service Manual
Management Server
System
Event Log
Error LED
Management Server
System
Event Log
Error LED
E-Mail
Call-Home
Sense Info
E-Mail
Call-Home
Sense Info
Host
Link Incident
Log
Host
Link Incident
Log

Advertisement

Table of Contents
loading

Table of Contents