IBM TotalStorage SAN32M-2 Installation And Service Manual page 280

Hide thumbs Also See for TotalStorage SAN32M-2:
Table of Contents

Advertisement

Event code: 508
Message:
Fibre Channel port anomaly detected.
Severity:
Informational.
Explanation:
The switch detected a deviation in the normal operating mode or status of the indicated Fibre Channel port.
Action:
No action required. An event code 506 is generated if this anomaly results in a hard port failure.
Event data:
Byte 0 = port number.
Byte 1 = anomaly reason code.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 and 9 = HA error callout #1.
Bytes 10 and 11 = HA error callout #2.
Distribution:
Product
EFCM Basic
Event Log
Event code: 510
Message:
Optical transceiver hot-insertion initiated.
Severity:
Informational.
Explanation:
Installation of an optical transceiver was initiated with the switch powered on and operational. The event indicates
operational firmware detected the presence of the transceiver.
Action:
No action required.
Event data:
Byte 0 = port number.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 11 = optic serial number.
Distribution:
Product
EFCM Basic
Event Log
254
SAN32M-2 Installation and Service Manual
Management Server
System
Event Log
Error LED
Management Server
System
Event Log
Error LED
Byte 12 = detecting port.
Byte 13 = connected port.
Bytes 16 and 17 = HA error callout #3.
Bytes 18 and 19 = HA error callout #4.