Event codes versus maintenance action (Continued)
Table 7
Event
code
Explanation
080
Unauthorized worldwide name.
081
Invalid attachment.
082
Port fenced.
083
Port set to inactive state.
120
Error detected while processing system management command.
121
Zone set activation failed - zone set too large.
140
Congestion detected on an ISL.
141
Congestion relieved on an ISL.
142
Low BB_Credit detected on an ISL.
143
Low BB_Credit relieved on an ISL.
150
Fabric merge failure.
151
Fabric configuration failure.
200
Power supply AC voltage failure.
201
Power supply DC voltage failure.
203
Power supply AC voltage recovery.
204
Power supply DC voltage recovery.
206
Power supply removed.
207
Power supply installed.
300
Cooling fan propeller failed.
301
Cooling fan propeller failed.
302
Cooling fan propeller failed.
303
Cooling fan propeller failed.
304
Cooling fan propeller failed.
305
Cooling fan propeller failed.
Action
Go to
MAP
0500.
Go to
MAP 0500
Go to
MAP
0600.
Go to
MAP 0500
Go to
Collect maintenance
Collect maintenance data
Reduce size of zone set and retry.
Go to
MAP
0600.
No action required.
Go to
MAP
0600.
No action required.
Go to
MAP
0600.
Go to
Collect maintenance
Collect maintenance data
Go to
MAP
0100.
Go to
MAP
0100.
No action required.
No action required.
Replace CRU.
No action required.
Go to
MAP
0400.
Go to
MAP
0400.
Go to
MAP
0400.
Go to
MAP
0400.
Go to
MAP
0400.
Go to
MAP