Event code: 411
Message:
Firmware fault.
Severity:
Major.
Explanation:
Switch firmware encountered an unexpected condition and dumped operating state information to FLASH
memory for retrieval and analysis. The dump file automatically transfers to the management server, where it is
stored for retrieval through a data collection.
The switch performs a software reset, during which all attached Fibre Channel devices are momentarily
disrupted, log out, and log back in.
Action:
Perform a data collection and return the CD to support personnel.
Event data:
Bytes 0 - 3 = fault identifier, least significant byte first.
Distribution:
Product
EFCM Basic
Event Log
Event code: 412
Message:
CTP watchdog timer reset.
Severity:
Informational.
Explanation:
The hardware watchdog timer expired and caused the CTP card to reset.
Action:
Perform a data collection and return the CD to support personnel.
Event data:
Byte 0 = reset type as follows: 00 = task switch did not occur within approximately one second,
01 = interrupt servicing blocked for more than approximately one second.
Distribution:
Product
EFCM Basic
Event Log
248
SAN32M-2 Installation and Service Manual
Management Server
System
Event Log
Error LED
Management Server
System
Event Log
Error LED
E-Mail
Call-Home
Sense Info
E-Mail
Call-Home
Sense Info
Host
Link Incident
Log
Host
Link Incident
Log

Advertisement

Table of Contents
loading

Table of Contents