126
SAN32M-2 Installation and Service Manual
Was the maintenance action successful?
NO
YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
5
An ISL connection is not allowed because one of the following
mode-mismatch conditions was detected:
The product is configured to operate in Open Fabric 1.0 mode
and is connected to a fabric element not configured to Open
Fabric 1.0 mode.
The product is configured to operate in Open Fabric 1.0 mode
and is connected to a legacy IBM switch at the incorrect
exchange link parameter (ELP) revision level.
The product is configured to operate in Open Fabric 1.0 mode
and is connected to a non-IBM switch at the incorrect ELP
revision level.
The product is configured to operate in McDATA Fabric 1.0
mode and is connected to a non-IBM switch.
Reconfigure the operating mode:
a. Set the product offline. Refer to
Edition) or
Set online state
b. For the product reporting the problem:
— EFCM Basic Edition - Select Switch and Fabric Parameters
from the Configure menu at any view. The Fabric
Parameters View displays.
— Element Manager - Select Operating Parameters and
Fabric Parameters from the Configure menu at any view.
The Configure Fabric Parameters dialog box displays.
c. Select McDATA Fabric 1.0 or Open Fabric 1.0 from the Interop
Mode drop-down list.
— Select McDATA Fabric 1.0 if the product is attached only to
other IBM directors or switches operating in McDATA Fabric
1.0 mode.
Set online state
(EFCM Basic
(Element Manager).