Enable Ethernet CFM

Task
Spawn the CFM process. No CFM configuration is
allowed until the CFM process is spawned.
Disable Ethernet CFM without stopping the CFM
process.

Create a Maintenance Domain

Connectivity Fault Management (CFM) divides a network into hierarchical maintenance domains, as
shown in the illustration in
Step
Task
1
Create maintenance domain.
2
Display maintenance domain information.
FTOS# show ethernet cfm domain
Domain Name: customer
Level: 7
Total Service: 1
Services
Domain Name: praveen
Level: 6
Total Service: 1
Services
Maintenance
Domains.
MA-Name
My_MA
MA-Name
Your_MA
Command Syntax
ethernet cfm
disable
Command Syntax
domain name md-level number
Range: 0-7
show ethernet cfm domain
]
brief
VLAN
CC-Int
200
10s
VLAN
CC-Int
100
10s
Command Mode
CONFIGURATION
ETHERNET CFM
Command Mode
ETHERNET CFM
[
|
EXEC Privilege
name
X-CHK Status
enabled
X-CHK Status
enabled