Dell Force10 S4810P Configuration Manual page 420

High-density, 1ru 48-port 10gbe switch
Hide thumbs Also See for Force10 S4810P:
Table of Contents

Advertisement

Figure 18-12. FIP Snooping Configuration Example
Enable the FIP snooping feature on the switch (FIP snooping bridge):
FTOS(conf)# feature fip-snooping
Enable FIP snooping on FCoE VLAN 10:
FTOS(conf)# interface vlan 10
FTOS(conf-if-vl-10)# fip-snooping enable
Enable an FC-MAP value on VLAN 10:
FTOS(conf-if-vl-10)# fip-snooping fc-map 0xOEFC01
Note: Configuring an FC-MAP value is only required if you do not use the default FC-MAP value
(0x0EFC00).
Configure the ENode server-facing port:
FTOS(conf)# interface tengigabitethernet 0/1
FTOS(conf-if-te-0/1)# portmode hybrid
FTOS(conf-if-te-0/1)# switchport
FTOS(conf-if-te-0/1)# protocol lldp
FTOS(conf-if-te-0/1-lldp)# dcbx port-role auto-downstream
Note: A port is enabled by default for bridge-ENode links.
Configure the FCF-facing port:
FTOS(conf)# interface tengigabitethernet 0/50
FTOS(conf-if-te-0/50)# portmode hybrid
FTOS(conf-if-te-0/50)# switchport
FTOS(conf-if-te-0/50)# fip-snooping port-mode fcf
FTOS(conf-if-te-0/50)# protocol lldp
FTOS(conf-if-te-0/50-lldp)# dcbx port-role auto-upstream
Configure FIP snooping ports as tagged members of FCoE VLAN:
FTOS(conf)# interface vlan 10
FTOS(conf-if-vl-10)# tagged tengigabitethernet 0/1
FTOS(conf-if-vl-10)# tagged tengigabitethernet 0/50
FTOS(conf-if-te-0/1)# no shut
FTOS(conf-if-te-0/50)# no shut
FTOS(conf-if-vl-10)# no shut
After FIP packets are exchanged between the ENode and the switch, a FIP snooping session is established.
ACLS are dynamically generated for FIP snooping on the FIP snooping bridge/switch.
420
|
FIP Snooping

Advertisement

Table of Contents
loading