Related Configuration Tasks

Enable CFM SNMP
Display Ethernet CFM

Enable Ethernet CFM

To enable the Ethernet CFM, use the following commands:
1
Spawn the CFM process. No CFM configuration is allowed until the CFM process is spawned.
CONFIGURATION mode
ethernet cfm
2
Disable Ethernet CFM without stopping the CFM process.
ETHERNET CFM
disable

Creating a Maintenance Domain

Connectivity fault management (CFM) divides a network into hierarchical maintenance domains, as shown in
Maintenance
Domains.
1
Create maintenance domain.
ETHERNET CFM mode
domain name md-level number
The range is from 0 to 7.
2
Display maintenance domain information.
EXEC Privilege mode
show ethernet cfm domain [name | brief]
Example of Viewing Configured Maintenance Domains
Dell# show ethernet cfm domain
Domain Name: customer
Level: 7
Total Service: 1
Services
MA-Name
VLAN
My_MA
200
Domain Name: praveen
Level: 6
Total Service: 1
Traps.
Statistics.
CC-Int
X-CHK Status
10s
enabled
802.1ag
103