Specify an Auto-failover Limit
When a non-recoverable fatal error is detected, an automatic failover occurs. However, FTOS is
configured to auto-failover only three times within any 60 minute period. You may specify a different
auto-failover count and period using the command redundancy auto-failover-limit.
To re-enable the auto-failover-limit with its default parameters, in CONFIGURATION mode, use the
redundancy auto-failover-limit
Disable Auto-reboot
Prevent a failed RPM from rebooting after a failover using the command
from CONFIGURATION mode.
Manually Synchronize RPMs
Manually synchronize RPMs at any time using the command
Privilege mode.
Switch Fabric Module redundancy
Switch Fabric Module Redundancy
Since the RPM on the C-Series also contains the switch fabric, even though the second RPM comes online
as the standby, the switch fabric is active and is automatically available for routing. Change this behavior
using the command
online, enter
online or taken offline. Use the command
Online Insertion and Removal
You can add, replace, or remove chassis components while the chassis is operating.
This section contains the following sub-sections:
•
RPM Online Insertion and Removal
•
Linecard Online Insertion and Removal
RPM Online Insertion and Removal
Dell Force10 systems are functional with only one RPM. If a second RPM is inserted, it comes online as
the standby RPM, as shown in the example below.
446
|
High Availability
command without parameters.
is supported on platform:
redundancy sfm standby
no redundancy sfm standby
redundancy synchronize full
c
from CONFIGURATION mode. To bring the secondary SFM
. There is sub-second packet-loss anytime an SFM is brought
to determine the status of the SFMs on the RPMs.
show sfm all
redundancy disable-auto-reboot
from EXEC