Logging Console - Dell PowerConnect 6024F Command Line Interface Reference Manual

Command line interface (cli) guide (.htm)
Hide thumbs Also See for PowerConnect 6024F:
Table of Contents

Advertisement

severity level—Limits the logging of messages to the syslog servers to a specified level:
emergencies, alerts, critical, errors, warnings, notifications, informational and
debugging. If unspecified, the default level is errors.
facility—The facility that is indicated in the message. Can be one of the following values:
local0, local1, local2, local3, local4, local5, local 6, local7. If unspecified, the port
number defaults to local7.
text—Syslog server description, which can be up to 64 characters.
Default Configuration
As described in the field descriptions.
Command Mode
Global Configuration mode
User Guidelines
Multiple syslog servers can be used.
If no specific severity level is specified, the global values apply to each server.
To define a logging server on the out-of-band port, use the out-of-band IP address format —
oob/ip-address.
Example
The following example configures messages with a "critical" severity level so that they are logged to
a syslog server with an IP address 10.1.1.1.
Console (config)# logging 10.1.1.1 severity critical

logging console

The logging console global configuration command limits messages logged to the console based on
severity. To disable logging to the console terminal, use the no form of this command.
Syntax
logging console level
no logging console
level—Limits the logging of messages displayed on the console to a specified level:
emergencies, alerts, critical, errors, warnings, notifications, informational, debugging.
Default Configuration
The default is informational.
412
Syslog Commands

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerconnect 6024

Table of Contents