startup direction—The alarm that may be sent when this entry is first set to valid. If the
first sample (after this entry becomes valid) is greater than or equal to the rthreshold, and
direction is equal to rising or rising-falling, then a single rising alarm is generated. If the
first sample (after this entry becomes valid) is less than or equal to the fthreshold, and
direction is equal to falling or rising-falling, then a single falling alarm is generated.
•
owner name—Enter a name that specifies who configured this alarm. If unspecified, the
name is an empty string.
Default Configuration
The following parameters have the following default values:
•
type type—If unspecified, the type is absolute.
•
startup direction—If unspecified, the startup direction is rising-falling.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the following alarm conditions:
•
Alarm index—1000
•
Variable identifier—dell
•
Sample interval—360000 seconds
•
Rising threshold—1000000
•
Falling threshold—1000000
•
Rising threshold event index—10
•
Falling threshold event index—20
Console (config)# rmon alarm 1000 dell 360000 1000000 1000000 10
20
show rmon alarm-table
The show rmon alarm-table user EXEC command displays the alarms summary table.
Syntax
show rmon alarm-table
341
RMON Commands