Edit User Authentication Timeout Settings - ZyXEL Communications NXC5200 User Manual

Hide thumbs Also See for NXC5200:
Table of Contents

Advertisement

Chapter 24 User/Group
Table 137 Configuration > Object > User/Group > Setting (continued)
LABEL
Maximum number per
administration
account
Limit the number of
simultaneous logons
for access account
Maximum number per
access account
User Lockout Settings
Enable logon retry
limit
Maximum retry count
Lockout period
Apply
Reset

24.4.1 Edit User Authentication Timeout Settings

This screen allows you to set the default authentication timeout settings for the
selected type of user account. These default authentication timeout settings also
control the settings for any existing user accounts that are set to use the default
settings. You can still manually configure any user account's authentication
timeout settings.
384
DESCRIPTION
This field is effective when Limit ... for administration
account is checked. Type the maximum number of
simultaneous logins by each admin user.
Select this check box if you want to set a limit on the number
of simultaneous logins by non-admin users. If you do not
select this, access users can login as many times as they want
as long as they use different IP addresses.
This field is effective when Limit ... for access account is
checked. Type the maximum number of simultaneous logins by
each access user.
Select this check box to set a limit on the number of times
each user can login unsuccessfully (for example, wrong
password) before the IP address is locked out for a specified
amount of time.
This field is effective when Enable logon retry limit is
checked. Type the maximum number of times each user can
login unsuccessfully before the IP address is locked out for the
specified lockout period. The number must be between 1 and
99.
This field is effective when Enable logon retry limit is
checked. Type the number of minutes the user must wait to try
to login again, if logon retry limit is enabled and the
maximum retry count is reached. This number must be
between 1 and 65,535 (about 45.5 days).
Click Apply to save the changes.
Click Reset to return the screen to its last-saved settings.