Trunk Anti-Tromboning - Nortel ICS Install Manual

Nortel norstar ics software: install guide
Hide thumbs Also See for ICS:
Table of Contents

Advertisement

158 / Private networking using PRI SL-1
5. Press CHANGE to choose either Y (yes) or N (no).

Trunk Anti-tromboning

TAT is a call-reroute feature that works to find better routes
during a transfer of an active call. This feature acts to prevent
unnecessary tandeming and tromboning of trunks. This action
occurs after the speech path has been established.
Note: This feature is not applicable for alerting calls.
This feature does not activate if TRO is set to yes.
Norstar configuration:
1. With the display showing System prgming press
' until the display shows NetworkServices.
2. Press ≠ until MCDN displays.
3. Press ≠. NetwkICCL: displays.
4. Press ' until TAT displays.
5. Press CHANGE to choose either Y (yes) or N (no).
Meridian configuration
The following must be set on the Meridian 1 before this feature
can activate:
MCDN PRI D-channel must have TAT set to yes (using
LD17 and TRMB in LD17)
1.5 MB/2MB DTI/PRI card configured as PRI with
interface type of SL1
NCRD parameter set to yes for the MCDN PRI routes
Remote capabilities configured for the D-channel (using
LD 17) to include ND2
Modular ICS 7.1 Installer Guide
N0130943 02