No Spids Assignd; Of B-Channels - Nortel ICS Install Manual

Nortel norstar ics software: install guide
Hide thumbs Also See for ICS:
Table of Contents

Advertisement

No SPIDs assignd

T and NT loops can be assigned a system profile identifier
(SPID) as supplied by your service provider. No SPIDs are
assigned by default.
When the loop type is T, calls on the loop are handled for a
network connection only. If any other ISDN equipment is
connected to the loop, it must be configured as an S loop to
ensure proper call handling.
1. Press ADD and enter the first or second SPID assigned to
the loop.
If there are two SPIDs already assigned to the loop, ADD
will not appear until one is removed.
2. Press REMOVE to clear a SPID.
Note: Profile 2 loops do not require SPIDs.

# of B-channels

Press CHANGE to select the number of B-channels that are
associated with the SPID: 1 or 2.
When you order an ISDN capability package that supplies two
B-channels, you may receive one or two SPIDs from your
service provider.
If you receive one, it usually means you will configure the
SPID to use two B-channels.
If you receive two, it usually means you will configure
each SPID with one B-channel. Check with your service
provider if you are not sure about the proper configuration.
N0130943 02
Hardware / 513
Modular ICS 7.1 Installer Guide