Out Of Service Displays When A Bri Is Selected (Led For Loop Is Lit); All The Leds On A Bri Card Are Flashing - Nortel ICS Install Manual

Nortel norstar ics software: install guide
Hide thumbs Also See for ICS:
Table of Contents

Advertisement

616 / Problems with BRI service
4. Test the network connection by connecting Bellcore
standard terminal equipment (TE) directly to the network.
5. Verify that the loop is provisioned.
6. Verify that the loop is properly configured, including the
proper loop type, SPIDs, and Network DNs.
7. Disable and re-enable the BRI Card.
8. Disable and enable the module for the Card.
Out of service displays when a BRI is selected
(LED for loop is lit)
Possible problem
The loop is configured incorrectly. Layer 1 is present but
Layers 2 and 3 are not working.
Solution
1. Verify that the SPIDs and Network DNs are programmed
correctly in Hardware.
2. Verify that the loop and lines are provisioned.

All the LEDs on a BRI Card are flashing

Possible problem
The card is not configured properly.
Solution
Verify that the loop is properly configured, including the
proper loop type, SPIDs, and Network DNs.
Modular ICS 7.1 Installer Guide
N0130943 02