If You See An Alarm Code - Nortel ICS Install Manual

Nortel norstar ics software: install guide
Hide thumbs Also See for ICS:
Table of Contents

Advertisement

If you see an alarm code

1. Write the alarm code on the Sys test log record.
2. Determine the cause of the alarm from the following table.
3. Follow Alarm troubleshooting on page 551.
4. Press TIME to see when the alarm occurred.
5. Press CLEAR to clear the alarm.
An alarm code may not be displayed until two minutes after it
has been triggered. If the ICS is powered off when the alarm is
triggered, the alarm code is not displayed until two minutes
after the ICS is powered on.
For a complete list of Norstar alarms, refer to the Norstar
Alarm & Event Code Manual.
Displays
Example
display
Alarm:
An error has occurred in
the download of a protocol
37 ABBC
to a BRI Card.
DD
N0130943 02
Meaning
A: the maintenance index
of the BRI
BB: a code describing the
nature of the error
C: the current download
state
DD (appears when the
error is limited to one
protocol): the two-
character product identifier
of the protocol
Alarm codes / 549
Possible causes
The BRI Card is not properly
installed.
Modular ICS 7.1 Installer Guide