564 / Provisioning BRI and PRI lines

L001

If the loop is configured as a U-NT, T or S loop, press
≠ and ' to display the individual lines.
There are no lines associated with an S or U-LT loop.
1. Press REMOVE to take the line out of service.
2. If line is busy, the display will ask if you still want to
remove it from service. Press YES to go ahead.

Provisioning a T1 line

Start with the display showing Network evt log.
1. Press '. Provisioning displays.
2. Select a module and card type, see Show module on page
496.
3. Press ≠. Show module: displays.
4. Enter the number of the line to be provisioned. The display
shows the line and its current status.
5. Press PORT to identify the logical port number for the line.
Lines cannot be provisioned from the PORT display. Press
LINE to return to the line number display.
6. Press ' to view settings for the next line number.
7. Press – until you return to Provisioning.

Provisioning a PRI line

ISDN lines are provisioned by default. For information on
adding a DTI card (configured as PRI) see Cards on KSU on
page 496.
Modular ICS 7.1 Installer Guide