Lenovo System x3550 M3 Problem Determination And Service Manual page 97

Table of Contents

Advertisement

1. Make sure that the latest levels of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that
the latest level of code is supported for the cluster solution before you update the code. 2. Update the
firmware (UEFI and IMM) to the latest level (Updating the firmware). 3. Run the DSA program. 4.
Reseat the adapter. 5. Replace the adapter. 6. (Trained technician only) Replace microprocessor n. 7.
(Trained technician only) Replace the system board. (n = microprocessor number)
• 806f0007-0302xxxx : [ProcessorElementName] has Failed with IERR. (CPU 2)
This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070302xxxx or 0x806f00070302xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0042
User Response
1. Make sure that the latest levels of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that
the latest level of code is supported for the cluster solution before you update the code. 2. Update the
firmware (UEFI and IMM) to the latest level (Updating the firmware). 3. Run the DSA program. 4.
Reseat the adapter. 5. Replace the adapter. 6. (Trained technician only) Replace microprocessor n. 7.
(Trained technician only) Replace the system board. (n = microprocessor number)
• 806f0008-0a01xxxx : [PowerSupplyElementName] has been added to container
[PhysicalPackageElementName]. (Power Supply 1)
This message is for the use case when an implementation has detected a Power Supply has been added.
May also be shown as 806f00080a01xxxx or 0x806f00080a01xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
.
Chapter 3
Diagnostics
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

42547944

Table of Contents