Lenovo System x3550 M3 Problem Determination And Service Manual page 231

Table of Contents

Advertisement

Automatically notify support
No
Alert Category
System - Power On
SNMP Trap ID
24
CIM Information
Prefix: PLAT ID: 0107
User Response
No action; information only.
• 816f000d-0400xxxx : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 0)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0400xxxx or 0x816f000d0400xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the
drive. 2. Replace the hard disk drive. 3. Make sure that the disk firmware and RAID controller firmware
is at the latest level. 4. Check the SAS cable.
• 816f000d-0401xxxx : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 1)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0401xxxx or 0x816f000d0401xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
.
Chapter 3
Diagnostics