Safety cover
Alignment
tabs
Figure 115. Safety cover removal
Step 6.
Disconnect the hard disk drive backplane cables from the connector on the front of the safety
cover.
Step 7.
Slide the safety cover forward to disengage it from the system board, then lift it out of the server.
Step 8.
Step 9.
If you are instructed to return the safety cover, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Installing the 240 VA safety cover
Use this information to install the 240 VA safety cover.
To install the 240 VA safety cover, complete the following steps:
Step 1.
Read the safety information that begins on
417.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the cover (see
Step 4.
Remove the SAS/SATA riser-card assembly (see
assembly" on page
Step 5.
Align the tabs on the bottom of the safety cover with the slots on the system board and lower the
safety cover into the system board.
System x3550 M3Problem Determination and Service Guide
498
Screw
"Safety" on page v
"Removing the cover" on page
450).
and
"Installation guidelines" on page
424).
"Removing the SAS/SATA RAID riser-card