Figure 29. Cover installation
Step 3.
Slide the cover toward the front of the server.
Step 4.
Make sure that the cover correctly engages all the inset tabs on the server.
Step 5.
Slide the server all the way into the rack until it latches.
Step 6.
Reconnect the external cables and power cords.
Removing the microprocessor 2 air baffle
Use this information to remove the microprocessor 2 air baffle.
To remove the microprocessor 2 air baffle, complete the following steps:
Step 1.
Read the safety information that begins on
417.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the cover (see
Step 4.
Lift the air baffle up, making sure that the tab comes out of the hole on the side of the power-supply
cage; then, remove the air baffle from the server and set it aside.
Attention: For proper cooling and airflow, replace the air baffle before you turn on the server.
Operating the server with the air baffle removed might damage server components.
System x3550 M3Problem Determination and Service Guide
426
Cover
Tab
"Safety" on page v
"Removing the cover" on page
and
"Installation guidelines" on page
424).