Lenovo System x3550 M3 Problem Determination And Service Manual page 67

Table of Contents

Advertisement

May also be shown as 800102020701xxxx or 0x800102020701xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Check power supply n LED. 2. Remove the failing power supply. 3. Follow actions for OVER SPEC
LED in Light path diagnostics LEDs. 4. (Trained technician only) Replace the system board. (n =
power supply number) Planar 3.3V : Planar 5V :
• 80010202-2801xxxx : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (CMOS Battery)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
May also be shown as 800102022801xxxx or 0x800102022801xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Check power supply n LED. 2. Remove the failing power supply. 3. Follow actions for OVER SPEC
LED in Light path diagnostics LEDs. 4. (Trained technician only) Replace the system board. (n =
power supply number)
• 80010204-1d01xxxx : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan 1A Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
May also be shown as 800102041d01xxxx or 0x800102041d01xxxx
.
Chapter 3
Diagnostics
55