Lenovo System x3550 M3 Problem Determination And Service Manual page 182

Table of Contents

Advertisement

Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0104
User Response
1. Make sure that the power supplies installed are with the same rating or wattage. 2. Reinstall the
power supplies with the same rating or wattage.
• 806f060d-0400xxxx : Array [ComputerSystemElementName] has failed. (Drive 0)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0400xxxx or 0x806f060d0400xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware is at the latest level. 2.
Make sure that the SAS cable is connected correctly. 3. Replace the SAS cable. 4. Replace the RAID
adapter. 5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0401xxxx : Array [ComputerSystemElementName] has failed. (Drive 1)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0401xxxx or 0x806f060d0401xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
System x3550 M3Problem Determination and Service Guide