Lenovo System x3550 M3 Problem Determination And Service Manual page 110

Table of Contents

Advertisement

Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0036
User Response
1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the
server), the air baffles are in place and correctly installed, and the server cover is installed and
completely closed. 2. Make sure that the heat sink for microprocessor n is installed correctly. 3.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0108-0a01xxxx : [PowerSupplyElementName] has Failed. (Power Supply 1)
This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01080a01xxxx or 0x806f01080a01xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0086
User Response
1. Reseat power supply n. 2. If the power-on LED is not lit and the power-supply error LED is lit,
replace power supply n. 3. If both the power-on LED and the power-supply error LED are not lit, see
Power problems for more information. (n = power supply number)
• 806f0108-0a02xxxx : [PowerSupplyElementName] has Failed. (Power Supply 2)
This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01080a02xxxx or 0x806f01080a02xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Power
System x3550 M3Problem Determination and Service Guide