Lenovo System x3550 M3 Problem Determination And Service Manual page 96

Table of Contents

Advertisement

Prefix: PLAT ID: 0810
User Response
1. Make sure that the connectors on fan n are not damaged. 2. Make sure that the fan n connectors
on the system board are not damaged. 3. Make sure that the fans are correctly installed. 4. Reseat
the fans. 5. Replace the fans. (n = fan number)
• 800b050c-2581xxxx : Non-redundant:Insufficient Resources for [RedundancySetElementName]
has asserted. (Backup Memory)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050c2581xxxx or 0x800b050c2581xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
2. Re-enable mirroring in the Setup utility.
• 806f0007-0301xxxx : [ProcessorElementName] has Failed with IERR. (CPU 1)
This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070301xxxx or 0x806f00070301xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0042
User Response
System x3550 M3Problem Determination and Service Guide