• 80070608-0a02xxxx : Sensor [SensorElementName] has transitioned to non-recoverable. (PS 2
VCO Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706080a02xxxx or 0x800706080a02xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
1. Check power supply n LED. 2. Replace power supply n. (n = power supply number) PS2 12V OC
Fault : PS2 12V OV Fault : PS2 12V UV Fault :
• 800b0008-1381xxxx : Redundancy [RedundancySetElementName] has been restored. (Power Unit)
This message is for the use case when an implementation has detected Redundancy was Restored.
May also be shown as 800b00081381xxxx or 0x800b00081381xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0561
User Response
No action; information only.
• 800b0108-1381xxxx : Redundancy Lost for [RedundancySetElementName] has asserted. (Power
Unit)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b01081381xxxx or 0x800b01081381xxxx
.