Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system board.
2. Replace the failing fan. (n = fan number) Fan 5B Tach :
• 80010204-1d06xxxx : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (Fan 6A Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going low
has asserted.
May also be shown as 800102041d06xxxx or 0x800102041d06xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system board.
2. Replace the failing fan. (n = fan number) Fan 6B Tach :
• 80010701-0c01xxxx : Numeric sensor [NumericSensorElementName] going high (upper non-
critical) has asserted. (Ambient Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010c01xxxx or 0x800107010c01xxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID