Lenovo System x3550 M3 Problem Determination And Service Manual page 179

Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0174
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware is at the latest level. 2.
Make sure that the SAS cable is connected correctly. 3. Replace the SAS cable. 4. Replace the RAID
adapter. 5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f0513-2582xxxx : A PCI SERR has occurred on system [ComputerSystemElementName]. (PCIs)
This message is for the use case when an implementation has detected a PCI SERR.
May also be shown as 806f05132582xxxx or 0x806f05132582xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0234
User Response
1. Check the PCI LED. 2. Reseat the affected adapters and riser card. 3. Update the server firmware
(UEFI and IMM) and adapter firmware. Important: Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of
code is supported for the cluster solution before you update the code. 4. Make sure that the adapter
is supported. For a list of supported optional devices, see http://www.ibm.com/systems/info/
x86servers/serverproven/compat/us/. 5. Remove both adapters. 6. Replace the PCIe adapters. 7.
Replace the riser cards.
• 806f052b-2101xxxx : Invalid or Unsupported firmware or software was detected on system
[ComputerSystemElementName]. (IMM FW Failover)
This message is for the use case when an implementation has detected an Invalid/Unsupported Firmware/
Software Version.
May also be shown as 806f052b2101xxxx or 0x806f052b2101xxxx
.