Lenovo System x3550 M3 Problem Determination And Service Manual page 161

Table of Contents

Advertisement

DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the
Advanced Settings Utility (ASU).
• 806f040c-2010xxxx : [PhysicalMemoryElementName] Disabled on Subsystem
[MemoryElementName]. (DIMM 16)
This message is for the use case when an implementation has detected that Memory has been Disabled.
May also be shown as 806f040c2010xxxx or 0x806f040c2010xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
1. Make sure the DIMM is installed correctly. 2. If the DIMM was disabled because of a memory fault
(memory uncorrectable error or memory logging limit reached), follow the suggested actions for that
error event and restart the server. 3. Check the IBM support website for an applicable retain tip or
firmware update that applies to this memory event. If no memory fault is recorded in the logs and no
DIMM connector error LED is lit, you can re-enable the DIMM through the Setup utility or the
Advanced Settings Utility (ASU).
• 806f040c-2011xxxx : [PhysicalMemoryElementName] Disabled on Subsystem
[MemoryElementName]. (DIMM 17)
This message is for the use case when an implementation has detected that Memory has been Disabled.
May also be shown as 806f040c2011xxxx or 0x806f040c2011xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0131
User Response
.
Chapter 3
Diagnostics
149

Advertisement

Table of Contents
loading

This manual is also suitable for:

42547944