Lenovo System x3550 M3 Problem Determination And Service Manual page 388

Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
Chapter 4 "Parts listing, Lenovo System x3550 M3 Type 4254 and 7944" on page 403
• See
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
Trained service technician.
• Go to the IBM support website at
tips, and new device drivers or to submit a request for information.
Symptom
The OVER SPEC LED on the
light path diagnostics panel is
lit, and the 12v channel D LED
on the system board is lit.
The OVER SPEC LED on the
light path diagnostics panel is
lit, and the 12v channel E LED
on the system board is lit.
The OVER SPEC LED on the
light path diagnostics panel is
lit, and the 12v channel AUX
LED on the system board is lit.
System x3550 M3Problem Determination and Service Guide
376
http://www.ibm.com/supportportal/
Action
1. Turn off the server and disconnect the power from the server.
2. (Trained service technician only) Remove the microprocessor in socket 1.
Note: The server will not power-on when the microprocessor in socket 1 or 2 is
not installed in the server. (Trained service technician only) Toggle the switch
block (SW4), switch 3 to allow the server to power-on. See
switches and jumpers" on page 18
the system board.
3. Restart the server to see whether the problem remains.
4. (Trained service technician only) Reinstall the microprocessor in socket 1 and
restart the server.
5. Replace any failing device.
6. (Trained service technician only) Replace the system board.
1. Turn off the server and disconnect the power from the server.
2. Remove the PCI riser card from PCI riser connector 2 and the microprocessor in
socket 2.
3. Restart the server to see whether the problem remains.
4. Reinstall each device that you removed in step 2 one at a time, starting the
server each time, to isolate the failing device.
5. Replace any failing device.
6. (Trained service technician only) Replace the system board.
1. Turn off the server and disconnect the power from the server.
2. Remove all PCI Express and PCI-X cards, all PCI riser cards, the operator
information panel, and the Ethernet adapter (if installed).
Note: The server will not power-on when the microprocessor in socket 1 or 2 is
not installed in the server. (Trained service technician only) Toggle the switch
block (SW4), switch 3 to allow the server to power-on. See
switches and jumpers" on page 18
the system board.
3. Restart the server to see whether the problem remains.
4. Reinstall each device that was removed in step 2 one at a time, starting the
server each time, to isolate the failing device.
5. Replace any failing device.
6. (Trained service technician only) Replace the system board.