May also be shown as 806f06070302xxxx or 0x806f06070302xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0816
User Response
1. Make sure that the installed microprocessors are compatible with each other (see Installing a
microprocessor and heat sink for information about microprocessor requirements). 2. Update the
server firmware to the latest level (see Updating the firmware). 3. (Trained technician only) Replace the
incompatible microprocessor.
• 806f0608-0a01xxxx : [PowerSupplyElementName] has a Configuration Mismatch. (Power Supply 1)
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
May also be shown as 806f06080a01xxxx or 0x806f06080a01xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0104
User Response
1. Make sure that the power supplies installed are with the same rating or wattage. 2. Reinstall the
power supplies with the same rating or wattage.
• 806f0608-0a02xxxx : [PowerSupplyElementName] has a Configuration Mismatch. (Power Supply 2)
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
May also be shown as 806f06080a02xxxx or 0x806f06080a02xxxx