Lenovo System x3550 M3 Problem Determination And Service Manual page 103

Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0132
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs). 2.
Update the server firmware on the primary page. Important: Some cluster solutions require specific
code levels or coordinated code updates. If the device is part of a cluster solution, verify that the
latest level of code is supported for the cluster solution before you update the code. 3. (Trained
technician only) Replace the system board. Firmware Error :
• 806f000f-220103xx : The System [ComputerSystemElementName] encountered firmware error -
unrecoverable boot device failure. (ABR Status)
This message is for the use case when an implementation has detected that System Firmware Error
Unrecoverable boot device failure has occurred.
May also be shown as 806f000f220103xx or 0x806f000f220103xx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0770
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response. Firmware Error :
• 806f000f-220104xx : The System [ComputerSystemElementName]has encountered a motherboard
failure. (ABR Status)
This message is for the use case when an implementation has detected that a fatal motherboard failure in
the system.
May also be shown as 806f000f220104xx or 0x806f000f220104xx
.
Chapter 3
Diagnostics
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

42547944

Table of Contents