Lenovo System x3550 M3 Problem Determination And Service Manual page 90

Table of Contents

Advertisement

Prefix: PLAT ID: 0530
User Response
1. See Power problems for more information. 2. Turn off the server and disconnect it from power. 3.
(Trained technician only) Replace the system board. 4. (Trained technician only) Replace the failing
microprocessor. Pwr Rail B Fault : Pwr Rail C Fault : Pwr Rail D Fault : Pwr Rail E Fault :
• 80070608-0701xxxx : Sensor [SensorElementName] has transitioned to non-recoverable. (VT Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706080701xxxx or 0x800706080701xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
1. Check power supply n LED. 2. Replace power supply n. (n = power supply number)
• 80070608-0a01xxxx : Sensor [SensorElementName] has transitioned to non-recoverable. (PS 1
VCO Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706080a01xxxx or 0x800706080a01xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
1. Check power supply n LED. 2. Replace power supply n. (n = power supply number) PS1 12V OC
Fault : PS1 12V OV Fault : PS1 12V UV Fault :
System x3550 M3Problem Determination and Service Guide
78

Advertisement

Table of Contents
loading

This manual is also suitable for:

42547944

Table of Contents