Power-Supply Leds - Lenovo System x3550 M3 Problem Determination And Service Manual

Table of Contents

Advertisement

Table 10. Light path diagnostics panel LEDs (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See "Parts listing" to determine which components are customer replaceable units (CRU) and which
components are field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
trained service technician.
Description
LED
DASD
A hard disk drive has failed or is
missing.
RAID
Reserved.
BRD
An error has occurred on the
system board.

Power-supply LEDs

Use this information to view power-supply LEDs.
The following minimum configuration is required for the server to start:
• One microprocessor in microprocessor socket 1
• One 2 GB DIMM for each microprocessor installed (one 2 GB DIMM in slot 3 if only one microprocessor
installed)
• One power supply
• Power cord
• Five cooling fans (fan 1, 2, 3, 4, and 5)
Action
1. Check the LEDs on the hard disk drives for the drive with a
lit status LED and reseat the hard disk drive.
2. Reseat the hard disk drive backplane.
3. For more information, see the "Hard disk drive problems".
4. If the error remains, replace the following components in
the order listed, restarting the server after each:
a. Replace the hard disk drive.
b. Replace the hard disk drive backplane.
5. If the error remains, replace the following components one
at a time, in the order listed, restarting the server after
each:
a. Replace the hard disk drive.
b. Replace the hard disk drive backplane.
6. If the problem remains, go to
entry/portal/docdisplay?lndocid=SERV-CALL
1. Check the LEDs on the system board to identify the
component that caused the error. The BRD LED can be lit
due to any of the following reasons:
• Battery
• Missing PCI riser-card assembly
• Failed voltage regulator
2. Check the system-error log for information about the error.
3. Replace any failed or missing replacement components,
such as the battery or PCI riser-card assembly.
4. If a voltage regulator has failed, (trained service technician
only) replace the system board.
http://www.ibm.com/support/
.
.