Lenovo System x3550 M3 Problem Determination And Service Manual page 89

Table of Contents

Advertisement

and completely closed. 2. Check the ambient temperature. You must be operating within the
specifications (see Features and specifications for more information). 3. Make sure that the heat sink
for microprocessor n. 4. (Trained technician only) Replace microprocessor n. (n = microprocessor
number)
• 80070301-2d01xxxx : Sensor [SensorElementName] has transitioned to non-recoverable from a
less severe state. (IOH Temp Status)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable from less severe.
May also be shown as 800703012d01xxxx or 0x800703012d01xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0524
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and correctly installed, and that the server cover is installed
and completely closed. 2. Check the ambient temperature. You must be operating within the
specifications (see Features and specifications for more information). 3. Make sure that the heat sink
for microprocessor n. 4. (Trained technician only) Replace microprocessor n. (n = microprocessor
number)
• 80070603-0701xxxx : Sensor [SensorElementName] has transitioned to non-recoverable. (Pwr Rail
A Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
May also be shown as 800706030701xxxx or 0x800706030701xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
.
Chapter 3
Diagnostics
77