May also be shown as 800702080a01xxxx or 0x800702080a01xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-
supply fan. 2. Use the IBM Power Configurator utility to determine current system power
consumption. For more information and to download the utility, go to http://www-03.ibm.com/
systems/bladecenter/resources/powerconfig.html. 3. Replace power supply n. (n = power supply
number) PS 1 Therm Fault :
• 80070208-0a02xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (PS 2 OP Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702080a02xxxx or 0x800702080a02xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-
supply fan. 2. Use the IBM Power Configurator utility to determine current system power
consumption. For more information and to download the utility, go to http://www-03.ibm.com/
systems/bladecenter/resources/powerconfig.html. 3. Replace power supply n. (n = power supply
number) PS 2 Therm Fault :
• 8007020f-2582xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (No I/O Resources)
System x3550 M3Problem Determination and Service Guide
74