1. Reseat power supply n. 2. If the power-on LED is not lit and the power-supply error LED is lit,
replace power supply n. 3. If both the power-on LED and the power-supply error LED are not lit, see
Power problems for more information. (n = power supply number)
• 806f0109-1381xxxx : [PowerSupplyElementName] has been Power Cycled. (Host Power)
This message is for the use case when an implementation has detected a Power Unit that has been power
cycled.
May also be shown as 806f01091381xxxx or 0x806f01091381xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0108
User Response
No action; information only.
• 806f010c-2001xxxx : Uncorrectable error detected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory uncorrectable error.
May also be shown as 806f010c2001xxxx or 0x806f010c2001xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0138
.