Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware is at the latest level. 2.
Make sure that the SAS cable is connected correctly. 3. Replace the SAS cable. 4. Replace the RAID
adapter. 5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0402xxxx : Array [ComputerSystemElementName] has failed. (Drive 2)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0402xxxx or 0x806f060d0402xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware is at the latest level. 2.
Make sure that the SAS cable is connected correctly. 3. Replace the SAS cable. 4. Replace the RAID
adapter. 5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0403xxxx : Array [ComputerSystemElementName] has failed. (Drive 3)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0403xxxx or 0x806f060d0403xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
.
Chapter 3